Heat Exchanger Tube Plugs, Plugging & Pressure-Testing Equipment
Valcon Valve & Controls is the sole South African distributor for EST Group (Curtiss-Wright): Pop-A-Plug heat exchanger tube plugs and plugging equipment, GripTight hydrostatic test plugs and pipe isolation plugs for pressure testing of piping, and tube and joint testing tools — supplied from Kempton Park and supported with on-site training for refineries, petrochemical plants, power stations (including nuclear), sugar mills and pulp and paper plants.
Approved supplier to Sasol, Eskom, Mondi, RCL, Ingrain, Sappi and others · ISO 9001
At a glance
| Tube plug range | Tube ID 0.400" to 2.067" (10.2 mm to 52.5 mm); to 7,000 psig (483 barg) with P2 plugs |
|---|---|
| Test plug range | Pipe DN10 to DN1200 (⅜" to 48"); to 15,000 psig (1,034 barg) |
| Materials | 40+ plug alloys matched to tube material — carbon steel, stainless, Duplex, brass, cupro-nickel, titanium, Inconel |
| Leak tightness | Helium leak-tight to 1×10⁻⁶ cc/sec (CPI/Perma) and 1×10⁻¹⁰ cc/sec (P2) |
| Standards | ASME PCC-2 (test and isolation plugs), ASME NQA-1, 10 CFR 50 App B, NUPIC, TÜV, ISO 9001 |
| Installation | Hydraulic ram, Smart Ram 640T battery tool (500 plugs per charge) |
Product range
| Brand | Series / model | Type | Size range | Pressure | Typical applications |
|---|---|---|---|---|---|
| EST Group | Pop-A-Plug CPI/Perma | Medium Pressure Tube Plug | Tube ID 0.472"–2.067" (12.0–52.5mm) | Up to 1,000 psig (68.9 barg) | Nuclear, refinery, petrochemical, power, pharmaceutical |
| EST Group | Pop-A-Plug P2 | High Pressure Tube Plug | Tube ID 0.400"–1.460" (10.2–37.1mm); min 0.215" | Up to 7,000 psig (483 barg) | Extreme thermal/pressure cycling; nuclear, refinery |
| EST Group | GripTight MAX | Hydrostatic Test Plug | DN10–DN1200 (3/8"–48") | Up to 15,000 psig (1,034 barg) | Pipe testing — steam, high alloy, FRP/GRE, wellhead |
| EST Group | GripTight Elbow | Elbow Test Plug | DN50–DN1200 (2"–48") | Up to 3,350 psig (231 barg) | Long radius elbow testing |
| EST Group | GripTight Isolation Plug / DBB | Pipe Isolation Plug | DN20–DN1200 (3/4"–48") | Up to 2,250 psig between seals | Hot work isolation, flange-to-pipe weld & test |
| EST Group | G-160 (Pressure), G-250 (Vacuum), G-650 (Joint) | Tube Testing Tool | Tube ID 0.28"–2.50" | 40–125 psig air supply | Heat exchanger tube & joint testing |
| EST Group | Smart Ram 640T | Battery-Operated Installation Tool | CPI: 0.472"–1.336"; P2: 0.400"–1.180" | N/A | Tube plug installation |
Plugging and pressure testing without welding
A Pop-A-Plug seals a leaking exchanger tube in minutes: pulling a tapered pin through a ring expands the ring against the tube wall with a controlled force that does not stress the tube-sheet joint — no welding, no hot-work permit, removable for retubing. The CPI/Perma plug covers most services to 1,000 psig; the P2 plug handles thermal and pressure cycling, feedwater heaters and nuclear service to 7,000 psig. GripTight MAX test plugs grip the inside of an open pipe end and seal it for hydrostatic testing to 15,000 psig on carbon steel, alloy, FRP/GRE and wellhead piping, cutting test time by up to 85% against welded end caps; GripTight Isolation plugs (ASME PCC-2) give a double block-and-bleed barrier inside the pipe so flange welds can be made and tested while the line stays isolated.