A pressure relief valve (PRV) opens gradually in proportion to overpressure and is used on liquid systems. A safety relief valve (SRV) opens rapidly with a snap action and is used on gas and vapour systems like steam boilers and compressors. The key difference is the opening mechanism: proportional vs pop action. A safety relief valve can serve both liquid and gas — making it the most common type in South African refineries and chemical plants. Valcon supplies the Farris range by Curtiss-Wright for all pressure relief valve applications in Southern Africa.
Pressure Relief Valve vs Safety Relief Valve — What’s the Difference?
You’re specifying a new pressure vessel, replacing an aging pressure relief valve on a boiler, or responding to an insurance audit in South Africa — and someone asks: “Is that a relief valve or a safety valve?” The terms get used interchangeably in South African plants, but they’re not the same thing. Getting it wrong can mean the wrong valve on the wrong service, which means failed inspections or, worse, a pressure relief valve that doesn’t protect the way it should.
This guide explains the difference between a safety valve and a relief valve in practical terms, so you can confidently specify the right pressure relief device for your application.
The Short Answer
Think of it like two types of emergency exit. A pressure relief valve is a door that opens gradually as the crowd pushes harder — it lets people out proportionally to the pressure. A safety valve is a fire escape that slams fully open the moment the alarm triggers — maximum flow, immediately, no half measures.
The engineering distinction comes down to how they open and what they protect.
| Feature | Pressure Relief Valve (PRV) | Safety Relief Valve (SRV) |
|---|---|---|
| Opening Action | Gradual / proportional — opens in proportion to overpressure | Snap action (pop) — opens rapidly and fully at set pressure |
| Primary Service | Liquid — water, oil, hydraulic fluids, thermal oil | Gas and vapour — steam, air, compressed gases, process vapour |
| Purpose | Regulate and stabilise system pressure within set limits | Emergency protection — prevent catastrophic overpressure |
| Overpressure to Full Lift | 10–25% above set pressure (gradual ramp) | 3–10% above set pressure (rapid full lift) |
| Reclosing | Yes — reseats when pressure drops below set point | Yes — reseats, but with a defined blowdown (typically 4–7%) |
| ASME Code | Section VIII (unfired pressure vessels) | Section I (boilers) or Section VIII depending on application |
| Typical Installation | Pumps, pipelines, hydraulic systems, liquid storage | Boilers, steam drums, compressors, gas receivers, reactors |
Why the Opening Action Matters
The key engineering difference between a pressure relief valve and a safety relief valve is the lift characteristic.
A pressure relief valve has a simple disc resting on a seat. As pressure builds past the set point, the disc lifts gradually — the higher the pressure, the more it opens. This proportional response is ideal for liquid systems where pressure rises are typically slow and steady (like thermal expansion in a pipeline).
A safety valve has a secondary control chamber (often called a huddling chamber or lip). When the safety valve cracks open, process pressure reaches this chamber and increases the effective area the pressure acts on. The result is a rapid snap to full lift — the valve goes from closed to fully open in milliseconds. This is essential for compressible gas and vapour services where pressure can spike suddenly and catastrophic quantities need to be vented fast.
What the ASME Codes Require for Pressure Relief Valves
ASME Section I — Boiler Safety Valves
Boiler safety valves must reach full lift within 3% overpressure and reseat within 4%. They carry a National Board “V” stamp. The open-yoke (exposed spring) design limits them to vapour service only. If your South African plant has fired boilers, the safety valves on the steam drum are Section I devices.
ASME Section VIII — Pressure Vessel Relief Valves
Safety relief valves on unfired pressure vessels (air receivers, heat exchangers, reactors, separators, storage tanks) must open within 10% overpressure and reseat within 7%. They carry a “UV” stamp. The enclosed spring design allows both vapour and liquid service.
In South African plants operating under SANS 347 (which references ASME), getting the pressure relief valve code designation right matters for insurance inspections and legal compliance.
When to Use Which — A Practical Guide for South African Plants
If your vessel can see both liquid and vapour conditions (common in chemical plants where flashing or two-phase flow is possible), you need a safety relief valve rated for both services.
The Farris Pressure Relief Valve Range — Supplied by Valcon in South Africa
Valcon Valve & Controls is the Southern African representative for Farris by Curtiss-Wright, one of the most widely installed safety relief valve and pressure relief valve brands in refineries and process plants worldwide. The Farris range covers the full spectrum of pressure relief applications:
All Farris pressure relief valves are ASME NB certified and available through Valcon with full sizing support, selection assistance, and after-sales service in Southern Africa.
Common Pressure Relief Valve Mistakes to Avoid
Using the terms interchangeably on spec sheets. An insurance inspector reviewing your pressure vessel documentation will notice if you’ve specified a “relief valve” on a steam system that requires a “safety valve” per ASME I. Get the terminology right — it’s not pedantic, it’s compliance.
Oversizing for “safety margin.” A pressure relief valve that’s too large for the system will chatter (rapid opening and closing), which damages the seat and reduces the valve’s life. Correct sizing matters more than going bigger.
Ignoring back pressure. If your pressure relief valve discharges into a common header with other valves, superimposed back pressure can reduce its capacity or prevent it from opening at the correct set pressure. A balanced bellows design (like the Farris 2600 with bellows option) compensates for this.
How Valcon Can Help
If you’re specifying, replacing, or auditing pressure relief valves or safety relief valves in a South African plant, Valcon’s technical team can help with valve selection, sizing calculations, and recommending the right Farris model for your application. We also support set-pressure testing and field service across Southern Africa.
Send us your process data sheet or vessel details and we’ll confirm the correct pressure relief valve type, size, and material.
Frequently Asked Questions
What is the difference between a pressure relief valve and a safety relief valve?
A pressure relief valve (PRV) opens gradually in proportion to overpressure and is designed for liquid service. A safety relief valve (SRV) opens with a rapid snap action at a set pressure and is designed for gas and vapour service. A safety relief valve can handle both liquid and gas, making it the most versatile option for process plants.
What is a safety valve vs a relief valve?
A safety valve is a spring-loaded device that opens fully and rapidly (pop action) to protect against sudden overpressure in gas or steam systems. A relief valve opens gradually to control and stabilise pressure in liquid systems. The distinction matters for ASME code compliance and insurance inspections in South Africa.
When should I use a pressure relief valve in South Africa?
Use a pressure relief valve on liquid-service applications such as thermal oil loops, hydraulic systems, water pipelines, and liquid storage vessels. For gas or vapour services like steam boilers, compressors, and process reactors, use a safety relief valve instead.
Who supplies Farris pressure relief valves in South Africa?
Valcon Valve & Controls is the authorised Southern African representative for Farris by Curtiss-Wright. Valcon supplies the full Farris range — Series 2600, 2700, 3800, and 1890 — with sizing support, selection assistance, and after-sales service from their base in Kempton Park, Gauteng.
What ASME code applies to pressure relief valves?
ASME Section I governs safety valves on boilers (must reach full lift within 3% overpressure, “V” stamp). ASME Section VIII governs safety relief valves on unfired pressure vessels (must open within 10% overpressure, “UV” stamp). South African plants operating under SANS 347 reference these ASME standards for pressure relief valve compliance.
Can I use a rupture disc instead of a pressure relief valve?
In some applications, yes — a bursting disc (rupture disc) can be used instead of or in combination with a pressure relief valve. Rupture discs offer faster response times and zero leakage, but they are single-use devices that must be replaced after activation. Many South African plants use a combination of both for optimal protection.